Which side of the window is fogging in your NYC apartment?
Winter fog on an accessible indoor glass surface and persistent haze inside a sealed glass unit are different observations. The first can occur when indoor air meets a cold surface. Moisture trapped between sealed panes calls for a glazing assessment. Cleaning the room-side surface cannot reach that space.
Locate the moisture safely
From inside, check whether a small area on the accessible room-side glass wipes clear. Avoid reaching outside, leaning through an opening or disturbing window guards. Record which windows are affected, time of day and whether the fog follows cooking, bathing, humidifier use or a cold night. Distinguish insulated glass from separate storm windows, where the space between panels is a different construction.
Compare patterns before buying equipment
If several windows fog on the room side after the same moisture-producing activity, check ventilation and indoor humidity. Recurrent haze confined within one sealed unit deserves a window contractor or building-envelope review. A cold frame or air leakage can contribute even when a room humidity reading looks ordinary. Andersen’s vapor-control guidance explains the relationship between surfaces, condensation and moisture control.
For an apartment humidity or airflow assessment, provide the affected surface, a room reading and the building’s glazing information. Ask management about damaged finishes or water entering around the opening.