Did duct sealing work? How to read a leakage test
The contractor sealed accessible duct joints in your townhouse. A warmer upstairs bedroom is welcome, but how much leakage did the work actually remove? Ask for the readings before and after the repair and a short description of what was tested.
Read the units and the boundary
A result marked CFM25 reports airflow at a test pressure of 25 pascals. It is different from the CFM delivered by a register during normal operation. Find out whether the number describes total duct leakage or leakage to outdoors. A result normalized by floor area cannot be compared directly with a raw CFM number. Confirm that the same system, boundary and test method appear on both records.
Apply the result to the original complaint
Suppose a comparable test drops from 160 to 80 CFM25. The measured leakage fell in half. That does not establish that half the heating bill disappeared or that one particular bedroom now receives its design airflow. If a room still feels weak, ask for its operating airflow to be evaluated separately. In a multifamily building, confirm which branches belong to your unit before authorizing work.
The Building America duct sealing checklist identifies testing as part of documenting the work. When discussing residential HVAC service, share both reports and flag any inaccessible sections that were excluded.