Can your existing system use a higher-MERV filter?
MERV describes how effectively a filter captures particles in specified size ranges. It is not a pressure-drop rating. Two filters with the same MERV can offer different resistance because their dimensions, media and effective surface areas differ.
Compare the filter at the airflow your system needs
Find the approved filter sizes and types in the air-handler or cabinet instructions. Ask for the proposed filter’s pressure-drop data at the design airflow, not just its MERV number. If the current rack is shallow, a deeper media cabinet is a separate installation decision. Its physical fit and service access also matter.
EPA’s MERV explanation describes particle capture and recommends using a level the system can accommodate. A visibly stronger air stream with a filter temporarily absent would not establish that operating without one is appropriate. The useful verification is delivered airflow and operating pressure with the proposed clean filter installed.
Decide who should inspect it
If the existing system already has weak airflow, address that before attributing the problem to filter grade. Have residential HVAC service record the installed filter, measured pressure and equipment limit. Keep the part number and a check interval based on actual loading so the performance observed with a clean filter continues through use.